EasyLife™ TCSPC
EasyLife™ TCSPC integrated lifetime system includs the comprehensive easy to use FeliXGX analysis software package, sample compartment with 10 mm thermostatable cuvette holder and 10 mm quartz cuvette, fast pmt (185 nm to 820 nm) with pre-amp and TCSPC PCI electronic board with acquisition software. One can easily measure lifetimes from 20 ps to 3 micro seconds. Please select appropriate nano-LED excitation sources (not included). Emission wavelength selection is by means of filters (not included). QuickStart video is included. PC workstation required, but not included.
Select LED(s)
TC 265
EasyLife excitation LED: 265 nm
TC 280
EasyLife excitation LED: 278 nm
TC 295
EasyLife excitation LED: 295 nm
TC 310
EasyLife excitation LED: 310 nm
TC 340
EasyLife excitation LED: 340 nm
TC 365
EasyLife excitation LED: 366 nm
TC 370
EasyLife excitation LED: 375 nm
TC 380
EasyLife excitation LED: 380 nm
TC 393
EasyLife excitation LED: 395 nm
TC 405
EasyLife excitation LED: 405 nm
TC 410
EasyLife excitation LED: 410 nm
TC 435
EasyLife excitation LED: 435 nm
TC 445
EasyLife excitation LED: 445 nm
TC 450
EasyLife excitation LED: 450 nm
TC 460
EasyLife excitation LED: 463 nm
TC 505
EasyLife excitation LED: 505 nm
TC 525
EasyLife excitation LED: 525 nm
TC 635
EasyLife excitation laser diode: 630 nm
TC 650
EasyLife excitation laser diode: 650 nm
LD 670
EasyLife excitation laser diode: 670 nm
Select Options
Options must be ordered at time of original purchase.
They cannot be added to the system later.
511
Stir provision for cuvette, must be ordered with original order, cannot be added later as option.
EasyLife™ TCSPC Accessories
500
One sheet polarizer with mounting hardware. Sheet polarizers have great acceptance angle, good throughput. Two required.
501
"Magic angle" polarizer
502
Cold Finger Dewar accessory designed to be used with liquid nitrogen as coolant (77 K). Includes: quartz cold finger Dewar that accepts 5 mm tubes, Dewar holder for the sample turret or single cuvette holder, foam lid for the Dewar and extension collar with altered sample chamber lid. Features a Suprasil quartz cold finger that passes light down to about 200 nm.
503
Solid sample holder
504
Set of (8) 1" round Longpass filters covering the wavelength range from 295–455 nm. Cut-off wavelengths are: 295, 305, 320, 380, 400, 420, 435 and 455 nm. The set is suitable for light sources from 280 to 435 nm and fluorophores emitting at wavelengths above 300 nm.
505
Set of (8) 1" round Longpass filters covering the wavelength range from 475–610 nm. Cut-off wavelengths are: 475, 495, 515, 530, 550, 570, 590 and 610 nm. The set is suitable for light sources from 280 to 580 nm and fluorophores emitting at wavelengths above 480 nm.
506
Set of (8) 1" round Longpass filters covering wavelength range from 630–1000 nm. Cut-off wavelengths are: 630, 665, 695, 715, 780, 830, 850 and 1000 nm. The set is suitable for light sources from 280 to 670 nm and fluorophores emitting at wavelengths above 650 nm.
516
Custom Filter Set. Select a set of 8 filters, your choice from 295–1,000 nm
507
Additional 1" diameter filter holder.
508
Neutral Density Filter Set for 300–2000 nm, +/- 5 % tolerance nominal. Includes: 0.1, 0.3, 0.5, 1.0, 2.0 and 3.0.
509
10 mm quartz cuvette
510
Micro cuvette with insert
512
Computer work station—recommended to guarantee software compatibility