EasyLife L

Your quote will include an EasyLife™ L luminescence lifetime system with a comprehensive easy to use software package, pulsed xenon lamp, sample compartment with 10 mm magnetic stir, 10 mm Peltier temperature-controlled cuvette holder and quartz cuvette. Also included are the special PMT detector and electronics. Workstation required, but not included.

 

EasyLife™ L

 

EasyLife™ L integrated system for LRET assays, phosphorescence and long lived luminescence. Includes: comprehensive easy to use FluoreScan software package, variable speed (up to 500 Hz) pulsed microsecond xenon lamp, sample compartment with variable speed magnetic stir and 10 mm Peltier temperature-contolled interchangeable cuvette holder and 10 mm quartz cuvette, special pmt detector (185 nm to 680 nm) and transient digitizer electronics. One can easily measure lifetimes from 200 ns to 300 ms. Extremely fast, single-shot decay acquisition and unique Timebased Lifetime Scan. Excitation and emission wavelength selection is by means of filters (not included). QuickStart video is included. Workstation required, but not included.

Select EasyLife™ L Accessories

520 Emission Filter: 289 nm
521 Emission Filter: 297 nm
522 Emission Filter: 308 nm
523 Emission Filter: 334 nm
524 Emission Filter: 350 nm
525 Emission Filter: 360 nm
526 Emission Filter: 370 nm
527 Emission Filter: 380 nm
528 Emission Filter: 390 nm
529 Emission Filter: 400 nm
530 Emission Filter: 400 nm
531 Emission Filter: 410 nm
532 Emission Filter: 420 nm
533 Emission Filter: 430 nm
534 Emission Filter: 440 nm
535 Emission Filter: 450 nm
536 Emission Filter: 460 nm
537 Emission Filter: 470 nm
538 Emission Filter: 480 nm
539 Emission Filter: 490 nm
540 Emission Filter: 500 nm
541 Emission Filter: 510 nm
542 Emission Filter: 520 nm
543 Emission Filter: 530 nm
544 Emission Filter: 540 nm
545 Emission Filter: 550 nm
546 Emission Filter: 560 nm
547 Emission Filter: 570 nm
548 Emission Filter: 580 nm
549 Emission Filter: 590 nm
550 Emission Filter: 600 nm
551 Emission Filter: 610 nm
552 Emission Filter: 620 nm
553 Emission Filter: 630 nm
554 Emission Filter: 640 nm
555 Emission Filter: 650 nm
500 One sheet polarizer with mounting hardware. Sheet polarizers have great acceptance angle, good throughput. Two required.
501 "Magic angle" polarizer
502 Cold Finger Dewar accessory designed to be used with liquid nitrogen as coolant (77 K). Includes: quartz cold finger Dewar that accepts 5 mm tubes, Dewar holder for the sample turret or single cuvette holder, foam lid for the Dewar and extension collar with altered sample chamber lid. Features a Suprasil quartz cold finger that passes light down to about 200 nm.
517 Front Face Solid Sample Holder. The front face solid sample holder, capable of rotational travel, was designed for the measurements of solid compounds, microscope slides, or films. The solid sample holder head mounts onto a base and can be removed easily to be substituted by a powder sample holder head.
518 Powdered Sample Holder. The powdered sample holder, capable of rotational travel, was designed for the measurements of powdered samples. The sample head can be disassembled for easy sample loading and cleaning.
556 Front Faced Powdered Sample Holder Head—Available only if 517 Powdered Sample Holder is Purchased
557 Powdered Sample Holder Head—Available only if 518 Powdered Sample Holder is Purchased
504 Set of (8) 1" round Longpass filters covering the wavelength range from 295–455 nm.  Cut-off wavelengths are: 295, 305, 320, 380, 400, 420, 435 and 455 nm. The set is suitable for light sources from 280 to 435 nm and fluorophores emitting at wavelengths above 300 nm.
505 Set of (8) 1" round Longpass filters covering the wavelength range from 475–610 nm. Cut-off wavelengths are: 475, 495, 515, 530, 550, 570, 590 and 610 nm. The set is suitable for light sources from 280 to 580 nm and fluorophores emitting at wavelengths above 480 nm.
506 Set of (8) 1" round Longpass filters covering wavelength range from 630–1000 nm. Cut-off wavelengths are: 630, 665, 695, 715, 780, 830, 850 and 1000 nm. The set is suitable for light sources from 280 to 670 nm and fluorophores emitting at wavelengths above 650 nm.
516 Custom Filter Set. Select a set of 8 filters, your choice from 295–1,000 nm
507 Additional 1" diameter filter holder.
508 Neutral Density Filter Set for 300–2000 nm, +/- 5 % tolerance nominal. Includes: 0.1, 0.3, 0.5, 1.0, 2.0 and 3.0.
509 10 mm quartz cuvette
510 Micro cuvette with insert 
512 Portable work station—recommended to guarantee software compatibility

Contact Information

* Required Information

*

First Name

*

Last Name

*

Company/Institution Name

*

Address

 

Address 2

*

City

*

State/Province

*

Zip/Postal Code

*

Country

*

Phone

 

Fax

*

Email

 

 
 
OBB has a policy of continuous product development and reserves the right to amend part numbers, descriptions and specifications without prior notice.
OBB

EasyLife™ L Quick Links

Lifetime Technique

Hardware

Software

Spefications

Accessories

Applications

Quote

OBB Links

Home

About Us

Service

Technical Notes

News

Events

Site Map

Contact OBB

Optical Building Blocks
300 Birmingham Rd
P.O. Box 186
Birmingham NJ 08011

Tel: 609-894-1541
Fax: 609-784-7809
E-mail: contact@OBB1.com